1 | #!/bin/bash
|
---|
2 | #
|
---|
3 | # This script deploys the HP ProLiant BIOS, Smart Array RAID controllers and
|
---|
4 | # iLO configurations previously captured on an HP ProLiant server to another
|
---|
5 | # HP ProLiant server.
|
---|
6 | # Some iLO configuration settings (IP, Administrator's password) can be
|
---|
7 | # customized through a file (config/ilo) on the USB key.
|
---|
8 | #
|
---|
9 | # October 2011
|
---|
10 |
|
---|
11 | clear
|
---|
12 | echo "*** Deploying Configuration ***"
|
---|
13 |
|
---|
14 | [ -f /ssstk/ssstk-functions ] && . /ssstk/ssstk-functions
|
---|
15 |
|
---|
16 | # Load the drivers and mount the USB key where the settings will be saved
|
---|
17 | ssstk_init
|
---|
18 |
|
---|
19 | # Deploy ProLiant BIOS configuration
|
---|
20 | dos2unix ${BIOS_FILE}
|
---|
21 |
|
---|
22 | hp-conrep -l -f${BIOS_FILE} -x ${CONREP_XML}
|
---|
23 | if [ $? = 0 ] ; then
|
---|
24 | echo "System Configuration data_files/conrep.dat APPLIED"
|
---|
25 | else
|
---|
26 | echo "System Configuration data_files/conrep.dat FAILED"
|
---|
27 | fi
|
---|
28 |
|
---|
29 | # Check if a Smart Array controler is installed and deploy the configuration
|
---|
30 | $IFHW_CMD ${HWDISC_FILE} "$ALLBOARDS" "PCI:Smart Array" 2> /dev/null
|
---|
31 | if [ $? = 0 ] ; then
|
---|
32 | dos2unix ${RAID_FILE}
|
---|
33 | hpacuscripting -reset -i ${RAID_FILE}
|
---|
34 | if [ $? = 0 ] ; then
|
---|
35 | echo "Array Configuration data_files/cpqacuxe.dat APPLIED"
|
---|
36 | else
|
---|
37 | echo "Array Configuration data_files/cpqacuxe.dat FAILED"
|
---|
38 | fi
|
---|
39 | else
|
---|
40 | echo "No Smart Array detected, no ACU Configuration applied."
|
---|
41 | fi
|
---|
42 |
|
---|
43 | # Check if an iLO interface is present and deploy its configuration
|
---|
44 | $IFHW_CMD ${HWDISC_FILE} "$ALLBOARDS" "PCI:Integrated Lights-Out" 2> /dev/null
|
---|
45 | if [ $? = 0 ] ; then
|
---|
46 | modprobe hpilo
|
---|
47 | # Source the customization file
|
---|
48 | [ -f ${ILO_CONFIG_FILE} ] && dos2unix ${ILO_CONFIG_FILE} && . ${ILO_CONFIG_FILE}
|
---|
49 | [ "x$ILO_IP" != "x" ] && OPTS="--ip $ILO_IP"
|
---|
50 | [ "x$ILO_NETMASK" != "x" ] && OPTS="$OPTS --netmask $ILO_NETMASK"
|
---|
51 | [ "x$ILO_GW" != "x" ] && OPTS="$OPTS --gw $ILO_GW"
|
---|
52 | [ "x$ILO_LICENSE" != "x" ] && OPTS="$OPTS --license $ILO_LICENSE"
|
---|
53 | [ "x$ILO_ADMIN_PASSWD" != "x" ] && OPTS="$OPTS --password $ILO_ADMIN_PASSWD"
|
---|
54 | # Do the cleanup and customization of the iLO config file
|
---|
55 | dos2unix ${ILO_FILE}
|
---|
56 | etreeiloclean.py $OPTS $ILO_FILE > ${ILO_UPDATED_FILE}
|
---|
57 | if [ -f ${ILO_UPDATED_FILE} ]; then
|
---|
58 | hponcfg -f ${ILO_UPDATED_FILE}
|
---|
59 | if [ $? = 0 ] ; then
|
---|
60 | echo "Integrated Lights-Out Configuration ${ILO_UPDATED_FILE} APPLIED"
|
---|
61 | else
|
---|
62 | echo "Integrated Lights-Out Configuration ${ILO_UPDATED_FILE} FAILED"
|
---|
63 | fi
|
---|
64 | else
|
---|
65 | echo "Integrated Lights-Out Configuration filtering of hponcfg.dat FAILED"
|
---|
66 | fi
|
---|
67 | fi
|
---|
68 |
|
---|
69 | # Copy the log files if any and unmount the key
|
---|
70 | ssstk_stop
|
---|