[1436] | 1 | #!/bin/bash
|
---|
| 2 | #
|
---|
| 3 | # This script deploys the HP ProLiant BIOS, Smart Array RAID controllers and
|
---|
| 4 | # iLO configurations previously captured on an HP ProLiant server to another
|
---|
| 5 | # HP ProLiant server.
|
---|
| 6 | # Some iLO configuration settings (IP, Administrator's password) can be
|
---|
| 7 | # customized through a file (config/ilo) on the USB key.
|
---|
| 8 | #
|
---|
| 9 | # October 2011
|
---|
| 10 |
|
---|
| 11 | clear
|
---|
| 12 | echo "*** Deploying Configuration ***"
|
---|
| 13 |
|
---|
| 14 | [ -f /ssstk/ssstk-functions ] && . /ssstk/ssstk-functions
|
---|
| 15 |
|
---|
| 16 | # Load the drivers and mount the USB key where the settings will be saved
|
---|
| 17 | ssstk_init
|
---|
| 18 |
|
---|
| 19 | # Deploy ProLiant BIOS configuration
|
---|
| 20 | dos2unix ${BIOS_FILE}
|
---|
| 21 |
|
---|
| 22 | hp-conrep -l -f${BIOS_FILE} -x ${CONREP_XML}
|
---|
| 23 | if [ $? = 0 ] ; then
|
---|
| 24 | echo "System Configuration data_files/conrep.dat APPLIED"
|
---|
| 25 | else
|
---|
| 26 | echo "System Configuration data_files/conrep.dat FAILED"
|
---|
| 27 | fi
|
---|
| 28 |
|
---|
| 29 | # Check if a Smart Array controler is installed and deploy the configuration
|
---|
| 30 | $IFHW_CMD ${HWDISC_FILE} "$ALLBOARDS" "PCI:Smart Array" 2> /dev/null
|
---|
| 31 | if [ $? = 0 ] ; then
|
---|
| 32 | dos2unix ${RAID_FILE}
|
---|
| 33 | hpacuscripting -reset -i ${RAID_FILE}
|
---|
| 34 | if [ $? = 0 ] ; then
|
---|
| 35 | echo "Array Configuration data_files/cpqacuxe.dat APPLIED"
|
---|
| 36 | else
|
---|
| 37 | echo "Array Configuration data_files/cpqacuxe.dat FAILED"
|
---|
| 38 | fi
|
---|
| 39 | else
|
---|
| 40 | echo "No Smart Array detected, no ACU Configuration applied."
|
---|
| 41 | fi
|
---|
| 42 |
|
---|
| 43 | # Check if an iLO interface is present and deploy its configuration
|
---|
| 44 | $IFHW_CMD ${HWDISC_FILE} "$ALLBOARDS" "PCI:Integrated Lights-Out" 2> /dev/null
|
---|
| 45 | if [ $? = 0 ] ; then
|
---|
| 46 | modprobe hpilo
|
---|
| 47 | # Source the customization file
|
---|
| 48 | [ -f ${ILO_CONFIG_FILE} ] && dos2unix ${ILO_CONFIG_FILE} && . ${ILO_CONFIG_FILE}
|
---|
[1437] | 49 | [ "x$ILO_IP" != "x" ] && OPTS="--ip $ILO_IP"
|
---|
| 50 | [ "x$ILO_NETMASK" != "x" ] && OPTS="$OPTS --netmask $ILO_NETMASK"
|
---|
| 51 | [ "x$ILO_GW" != "x" ] && OPTS="$OPTS --gw $ILO_GW"
|
---|
| 52 | [ "x$ILO_LICENSE" != "x" ] && OPTS="$OPTS --license $ILO_LICENSE"
|
---|
| 53 | [ "x$ILO_ADMIN_PASSWD" != "x" ] && OPTS="$OPTS --password $ILO_ADMIN_PASSWD"
|
---|
[1436] | 54 | # Do the cleanup and customization of the iLO config file
|
---|
| 55 | dos2unix ${ILO_FILE}
|
---|
| 56 | etreeiloclean.py $OPTS $ILO_FILE > ${ILO_UPDATED_FILE}
|
---|
| 57 | if [ -f ${ILO_UPDATED_FILE} ]; then
|
---|
| 58 | hponcfg -f ${ILO_UPDATED_FILE}
|
---|
| 59 | if [ $? = 0 ] ; then
|
---|
| 60 | echo "Integrated Lights-Out Configuration ${ILO_UPDATED_FILE} APPLIED"
|
---|
| 61 | else
|
---|
| 62 | echo "Integrated Lights-Out Configuration ${ILO_UPDATED_FILE} FAILED"
|
---|
| 63 | fi
|
---|
| 64 | else
|
---|
| 65 | echo "Integrated Lights-Out Configuration filtering of hponcfg.dat FAILED"
|
---|
| 66 | fi
|
---|
| 67 | fi
|
---|
| 68 |
|
---|
| 69 | # Copy the log files if any and unmount the key
|
---|
| 70 | ssstk_stop
|
---|